Warranty & Registration Lookup
Register your Rheem product or verify your warranty terms and coverage.
Find a Pro
Put your water heater and heating and cooling system installation in good hands with a trustworthy, independent Rheem Pro.
Replace a Part
Find what you need to keep your Rheem equipment working perfectly.
Blogs
Read articles and industry news for homeowners and contractors.
Financing
Don’t let a limited budget keep you from getting the comfort equipment you need for your home or business.
FAQs
Get answers to all the most frequently asked questions (FAQs) about Heating, Cooling & Water Heating.
Who We Are
Learn more about Rheem, our history and our commitment to sustainability.
Sustainability
Learn about our commitment to doing good by our customers, our partners, our employees - and our planet.
Careers
Passionate, innovative thinkers work here, grow here and impact the next generation. We are driven to provide the perfect degree of comfort for homes and businesses.
Our Leadership
Find detailed profiles of our company's key executives, highlighting their professional backgrounds, expertise, and roles within the organization.
News Releases
Stay up to date with the latest news and press releases from Rheem Manufacturing and its family of brands.
Blogs
Read articles and industry news for homeowners and contractors.
svg-icon
Residential Products
svg-icon
HomeProductsCommercialHeating and CoolingRKNL-B, RKNL-C, RKNL-G, RKNL-H (15-25 Ton)

RKNL-B, RKNL-C, RKNL-G, RKNL-H (15-25 Ton)

MODEL RKNL-B210CM35EAJG

Parts - 1 year

Condenser Coil and Evaporator Coil leaks caused by factory defects - 5 Years

Compressor 1-Phase, 12 SEER models - 10 Years

Compressor 3-Phase models - 5 Years

  • ClearControl on RKNL-C Models
  • HumidiDry (Reheat) on RKNL-G Models
  • ClearControl and VFD Technology on RKNL-H
  • Three Phase Only
  • R-410A
  • Scroll Compressor
Select Tonnage
15.67
Tons
17.67
Tons
20.33
Tons
26
Tons

SKURKNL-B210CM35EAJG
ModelRKNL-B (15-25 Ton)
Tonnage17.67
FuelElectric
Depth152.0625"
Height57"
Width85.90625"
Install LocationOutdoor
Nominal Capacity in BTUH212000
Gross Capacity in BTUH212000

The 15-25 ton Rheem 3 phase RKNL-B,C Package Gas/Electric units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. The design is certified by CSA International.

RLNL-G units also feature HumidiDry, the Rheem exclusive dehumidification package unit solution.  HumidiDry delivers maximum humidity control without compromising desired temperature set point for a high degree of comfort by delivering dry neutral air when in the dehumidification mode.  The HumidiDry rooftop maintains humidity levels even when there's little or no demand for air conditioning.

Additional Benefits

ClearControl
Factory Installed ClearControl, a Direct Digital Control (DDC) and sensors which can connect to LonWorks or BACnet® BAS systems for remote monitoring and control.

The Scroll® Compressor
All of our residential/commercial package units, regardless of efficiency level, feature the Scroll® Compressor. The scroll compressor uses a more advanced technology than traditional reciprocating compressors.  Scroll compressors with internal line break overload and high pressure protection. Units are equipped with dual stage compressors. They have fewer moving parts, and they are quieter, more efficient, and longer lasting. Single stage compressor on C072 model. Dual stage compressor on C090 – C151 models.

Durable Cabinet with Louvered Condenser Compartment
Our cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a one-piece top cover and one piece base pan with drawn supply and return opening for superior water management. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Slide Out Indoor fan assembly for added service convenience. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers.

Motor/Fan Motor Mount
Our motor mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design.

Furnace Compartment
Control box operational controls are “up front” for quick access and service diagnostics.  The draft inducer motor is specially designed to quietly provide combustion air while simultaneously venting outdoors the combustion products from the furnace heat exchanger. In addition to the draft inducer motor, the in-shot gas burners, gas valve and manifold efficiently regulate the flow of gas for combustion.  These new gas/electric units also feature direct-spark ignition and remote flame sensors for added dependability and efficiency

Matched Blower/Evaporator Coil Unit
The blower is responsible for the flow of air into your ductwork. Single slab, single pass designed evaporator coil facilitate easy cleaning for maintained high efficiencies. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards.

Tubular Heat Exchanger
Our new package gas electric units feature a tubular heat exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers.

Other Benefits

  • There are single point electrical and gas connections on all models.
  • Solid Core liquid line filter drier on each circuit.
  • Rugged base rails are included for improved installation and handling.
  • Complete factory charged, wired and run tested.
  • Cooling operation up to 125 degree F ambient.
  • Convertible airflow- vertical downflow or horizontal sideflow.
  • TXV refrigerant metering system on each circuit.
  • High Pressure and Low Pressure/Loss of charge protection standard on all models.
  • 2 inch filter standard with slide out design.
  • Two stage gas valve, direct spark ignition, and induced draft for efficiency and reliability.
  • Solid state furnace control with on board diagnostics.
  • 24 volt control system with resettable circuit breakers.
  • Colored and labeled wiring.
  • Capillary tube refrigerant metering system on each circuit.

Parts - 1 year

Condenser Coil and Evaporator Coil leaks caused by factory defects - 5 Years

Compressor 1-Phase, 12 SEER models - 10 Years

Compressor 3-Phase models - 5 Years