Equipment | current | amended standards |
---|---|---|
Gas Fired Storage |
TE = 80%
SL = Q/800 + 110(Vr)1/2
|
TE = 80%
SL = Q/800 + 110(Vr)1/2
|
Gas-Fired Instantaneous |
TE = 80%
SL (≥10gal) = Q/800 + 110(Vr)1/2
|
TE = 95%
SL = 0.86*(Q/800 + 110(Vr)1/2)
|
Residential-Duty Commercial Gas-Fired Storage |
Medium Draw Pattern
UEF=0.6002-(0.0011xVr)
|
Medium Draw Pattern
UEF=0.8702-(0.0011xVr)
|
High Draw Pattern
UEF=0.6597-(0.0009xVr)
|
High Draw Pattern
UEF=0.9297-(0.0009xVr)
|